Building Bulletin (BB) 101 (BB101) is a set of regulations and standards that provide guidance on ventilation, indoor air quality and thermal comfort in school buildings. The Department for Education (DfE) provides this guidance for all types of school buildings in England, including temporary and modular classroom spaces which have seen a real surge in use as schools look to accommodate growing student numbers. This has seen ventilation in temporary classrooms become updated to provide more healthy and productive learning environments. 

In this guide, MPB Temporary Classrooms is here to explain Building Bulletin 101 and the classroom ventilation requirements in the UK, so you know what is required when specifying a modular classroom for your school. 

What Is Building Bulletin 101?

Building Bulletin 101 is a technical guidance document published by the Department for Education. It sets out design and performance guidance for ventilation, thermal comfort and indoor air quality in schools in England. 

The guidance covers how classrooms should receive adequate fresh air, manage indoor pollutants and maintain suitable temperatures during occupied hours. It considers different ventilation methods and how building design can reduce the risk of overheating. 

BB101 is used alongside Approved Document F of the Building Regulations when designing school ventilation systems in England. It is guidance rather than a single UK-wide legal standard, so requirements elsewhere in the UK must be checked separately. 

For schools considering temporary or modular classrooms that typically end up being permanent structures on a school site, BB101 provides a useful reference when assessing ventilation specifications and the suitability of additional teaching space. 

Marshlands 1 1

Why Air Quality and Ventilation Matter in Classrooms

Proper ventilation in classroom and school environments is essential for healthy and productive learning. 

Effective ventilation brings fresh outdoor air into classrooms while removing stale air, excess heat and indoor pollutants. According to the DfE, good ventilation can improve pupils’ alertness and concentration, help prevent overheating and reduce the build-up of polluted air. 

It can be quite easy for classrooms to become poorly ventilated when large numbers of pupils and staff occupy an enclosed space. As people breathe, they release carbon dioxide (CO2), which can accumulate when there is insufficient fresh air entering the room. 

Monitoring CO2 levels can help schools identify poorly ventilated classrooms and determine when ventilation needs to be increased or adapted. This is particularly useful when balancing fresh air supply with comfortable indoor temperatures during colder weather. 

The same considerations apply to ventilation in a portable or modular classroom, where the ventilation system should be appropriate for the room’s size, occupancy and intended use. 

What Are the Classroom Ventilation Requirements?

Ventilation in school classrooms should provide an adequate supply of fresh outdoor air, remove stale air and support comfortable indoor temperatures. In England, BB101 provides design and performance guidance for school buildings, while the DfE also offers practical guidance for monitoring ventilation in occupied classrooms. 

The DfE’s February 2026 guidance, which follows the last update from 2018, uses CO2 levels, measured in parts per million (ppm), to assess how well a classroom is ventilated:

  • Below 800 ppm: Good ventilation.
  • 800 – 1,500 ppm: Adequate ventilation.
  • Above 1,500 ppm: Poor ventilation, indicated that additional fresh air is needed.

These figures provide a practical way for schools to assess ventilation during everyday use. They should not be confused with the design and performance criteria set out in BB101. 

CO2 Monitoring in Classrooms

CO2 monitoring helps schools assess how much fresh air is reaching an occupied classroom. As pupils and staff breathe, CO2 levels rise and will continue to do so, especially when ventilation is insufficient for the number of people in the room. 

The DfE recommends regular monitoring and advises that one correctly positioned CO2 sensor is generally sufficient for a typical classroom. However, CO2 readings are an indicator of ventilation effectiveness rather than a complete measure of indoor air quality.

Natural Ventilation

Natural ventilation uses openable windows, doors and vents to bring outdoor air into classrooms and allow stale air to escape. It can provide effective ventilation without relying on mechanical systems, provided the building is designed and operated appropriately. 

However, its effectiveness depends on weather conditions and how openings are used. Cold temperatures, external noises, security considerations and outside air pollutants can all limit when and how windows, doors and vents can be opened.

Mechanical Ventilation

Mechanical ventilation uses fans, ducts or purpose-designed ventilation units to supply fresh outdoor air and remove stale air from classrooms. These systems can provide a more controlled airflow where opening windows is impractical. 

It is important to distinguish ventilation from cooling. Standard air conditioning systems may cool or recirculate indoor air without introducing fresh outdoor air, so air conditioning alone does not necessarily meet a classroom’s ventilation requirements.

Hybrid or Mixed-Mode Ventilation

Hybrid ventilation, also known as mixed-mode ventilation, combines natural and mechanical methods to manage classroom airflow. 

For example, a classroom may use openable windows when outdoor conditions are suitable, with mechanical ventilation providing additional airflow when required. The balance between the two methods depends on the building’s design, occupancy levels, weather conditions and the needs of the learning space.

20250808 125829

How Does BB101 Apply to Temporary and Modular Classrooms?

The requirements for ventilation in permanent, temporary and modular classrooms are no different. Schools must still consider ventilation, indoor air quality and thermal comfort as early as possible in specification and design. Requirements are generally based on the expected occupancy levels of the modular classroom, in addition to room layout, site conditions, acoustics and external air quality. 

Requirements can vary with each modular classroom project, and even the materials used can affect ventilation and air quality requirements, as certain materials used may contain higher concentrations of formaldehyde and other airborne chemicals. 

For schools planning temporary or permanent accommodation with modular construction, it is important to establish how the proposed ventilation system will perform during everyday teaching, particularly when classrooms are fully occupied or windows cannot be opened comfortably.

Ventilation Options When Buying a Modular Classroom

When buying a modular classroom, schools can consider natural, mechanical or hybrid ventilation systems, alongside CO2 monitoring equipment. The most appropriate arrangement depends on the number of pupils, classroom activities, location, external noise, overheating risk and available budget. 

Ventilation should be considered alongside the classroom’s overall layout and specification. Decisions about modular classroom sizes and planning, window positions and internal arrangements can all influence how effectively fresh air circulates through the space.

Natural Ventilation Options

The most common type of natural ventilation is provided through openable windows, wall vents and other purpose-designed openings. Their size and positioning influence how fresh air enters the classroom and how stale air escapes. 

When specifying a modular classroom, schools should consider whether the windows and vents can be easily controlled by staff throughout both the warmer and colder weather. Well-planned openings can provide fresh air while reducing uncomfortable draughts, although their effectiveness will still depend on outdoor conditions.

Mechanical and Demand-Controlled Ventilation

Mechanical ventilation systems use fans and ventilation units to supply fresh outdoor air and extract stale air safely. They can be useful where external noise, air pollution or security considerations make natural ventilation less practical. 

Some systems offer demand-controlled ventilation, automatically adjusting airflow in response to CO2 levels, occupancy or temperature. Depending on the design, mechanical ventilation can also be combined with openable windows to create a hybrid system. 

Schools should establish how the proposed system supplies fresh air, how it is controlled and what maintenance it will require.

CO2 Sensors and Ongoing Monitoring

Many modern CO2 sensors can be connected to a wireless network and accessed through a computer, or simply use them as standalone units with readings found on the sensor screens. No matter how you monitor results, it’s best to do it periodically and position carbon dioxide sensors away from doors, windows and ventilation outlets, and at least 0.5m away from occupants. 

Consistently elevated CO2 readings may indicate that the classroom needs additional fresh air or that the ventilation system requires adjustment. Monitoring is especially beneficial when occupancy levels change or during colder months when windows may remain closed.

New Single Modular Classroom 3

Questions to Ask When Specifying a Temporary Classroom

When planning a temporary or modular classroom, it is worth discussing ventilation requirements with your supplier early in the design process. Some useful questions to ask include:

  • Occupancy: How many pupils and staff will the classroom accommodate, and has the ventilation been designed for this number?
  • Ventilation System: Will the classroom use natural, mechanical or hybrid ventilation, and how will fresh air be supplied?
  • CO2 Monitoring: Will CO2 sensors be included, and how can staff monitor ventilation during lessons?
  • Heating and Overheating: How will the classroom maintain comfortable temperatures in winter and reduce overheating during warmer months?
  • Noise: Will external noise or the operation of ventilation equipment affect teaching and learning?
  • Outdoor Air Quality: Are there nearby roads or other pollution sources, such as nearby carparks, that could influence the ventilation design?
  • Maintenance: What servicing, filter replacement or other maintenance will the ventilation system require?
  • Documentation: What design calculations, specifications and compliance documentation will be provided to demonstrate how the proposed classroom meets applicable requirements?

Can Ventilation in an Existing Temporary Classroom Be Improved?

Yes, there are several ways to improve ventilation in an existing temporary classroom, and improvement should be made in line with any changes in CO2 levels you are monitoring. The most appropriate measures will depend on the building and its current ventilation system. 

Start by checking that openable windows and vents are working correctly and are not obstructed. Where mechanical ventilation is installed, ensure that systems are maintained, filtered are checked and airflow settings are appropriate for the classroom’s occupancy. 

Regular CO2 monitoring will identify rooms where fresh-air provision may be insufficient. Schools considering used classrooms should assess the existing ventilation arrangements and whether they are suitable for the proposed number of occupants. 

Where providing additional outdoor air is difficult, air cleaning units (ACUs) may help reduce certain airborne contaminants. However, the DfE’s ventilation guidance makes clear that air cleaning units are not a substitute for ventilation and do not reduce CO2 levels. If improving ventilation in an existing classroom will involve buying a new ACU, always follow the DfE’s procurement advice. 

If ventilation remains poor despite routine checks, or if alterations to the existing system are being considered, a specialist assessment can help identify suitable improvements. 

Plan Your Temporary Classroom With Air Quality in Mind

Classroom ventilation requirements and indoor air quality should be considered alongside heating, insulation, classroom layout and expected occupancy from the very initial planning stages. 

At MPB Temporary Classrooms, we understand the importance of Building Bulletin 101 and can help schools consider ventilation and thermal comfort requirements when planning their classroom accommodation. 

We offer modular classroom solutions for schools looking to purchase new accommodation, arrange temporary classroom hire or explore used classroom options. Discussing your requirements early provides an opportunity to consider suitable ventilation arrangements as part of the wider building specification. 

If your school is planning additional classroom space, get in touch with MPB Temporary Classrooms to discuss your requirements and available options. 

Get a Quick Quote

Frequently Asked Questions

What Is Building Bulletin 101?

Building Bulletin 101 (BB101) is the Department for Education’s guidance covering ventilation, indoor air quality and thermal comfort in school buildings in England. It provides design and performance criteria for teaching spaces and is used alongside Approved Document F of the Building Regulations. It is not a single UK-wide legal standard.

Does Building Bulletin 101 Apply to Modular Classrooms?

Yes, Building Bulletin 101 is relevant when designing and specifying modular classrooms for schools in England. Temporary accommodation still needs appropriate ventilation, indoor air quality and thermal comfort. The applicable requirements depend on factors such as the building’s intended use, occupancy, design and whether it is a new installation or an existing classroom.

What Is a Good CO2 Level in a Classroom?

According to the Department for Education’s guidance, CO2 levels below 800 parts per million (ppm) indicate good ventilation. Readings between 800 and 1,500 ppm indicate adequate ventilation, while levels above 1,500 ppm suggest poor ventilation. These figures help schools assess fresh-air provision in occupied classrooms.

Can Air Conditioning Replace Classroom Ventilation?

Not necessarily. Standard air conditioning systems often cool and recirculate indoor air without introducing fresh outdoor air. A classroom still needs adequate ventilation to remove stale air and indoor pollutants. Some systems combine air conditioning with fresh-air ventilation, so schools should check what their proposed equipment actually provides.

How Do You Ventilate a Temporary Classroom in Winter?

Temporary classrooms can be ventilated in winter by opening windows or vents sufficiently to introduce fresh air while maintaining comfortable temperatures. Where suitable, mechanical ventilation can provide a more controlled supply of outdoor air. Schools should monitor CO2 levels, avoid blocking ventilation openings and ensure heating and ventilation systems are working correctly.

Are Used Modular Classrooms Insulated?

Used modular classrooms can be insulated, but the exact specification will depend on the age, condition and original construction of the building. Schools should check the walls, roof, floor, glazing and seals before choosing a unit. Heating can also be added or upgraded during refurbishment.